Apc Device Configuration Wizard
How do I configure APC Network Management Card network settings Issue. An APC Network Management Card must be configured with network settings before it can communicate on the network. Once the cards have been configured with an IP address, Subnet Mask, and Default Gateway the cards can be accessed, managed, and controlled from other computers on the network. There are multiple configuration options available, outlined below, for each family of Network Management Cards or devices that have embedded versions of these products. How To Use This Manual. This is the manual for apcupsd, a daemon for communicating with UPSes Uninterruptible Power Supplies made by American Power Conversion. When the Configuration wizard gets stuck at importing sample maps, you can find an ERROR IISHelper Webrequest for OrionLogin. ConfigurationWizard. Product Line. Devices with an embedded WebSNMP Card include but are not limited to Environmental Monitoring Unit 1 AP9. TH Network Management Card 1 NMC1 AP9. AP9. 61. 8, AP9. 61. Devices with an embedded Network Management Card 1 include but are not limited to MeteredSwitched Rack PDUs AP7. XX, AP7. 9XX, Rack Automatic Transfer Switches AP7. XX, Environmental Monitoring Units AP9. AP9. 34. 0, Netbotz 2. Network Management Card 2 NMC2 AP9. AP9. 63. 0CH, AP9. AP9. 63. 1CH, AP9. Apc Device Configuration Wizard' title='Apc Device Configuration Wizard' />Issue An APC Network Management Card must be configured with network settings before it can communicate on the network. Once the cards have been configured with an IP. Release Notes for AP88XX Metered Rack PDUs and AP89xxAP86xx Switched Rack PDUs for Application Module v6. APC OS AOS v6. 4. APC PowerNet MIB v415. APC Device IP Configuration Wizard apcutilg. You can use the APC Device IP Configuration Wizard to configure the basic TCPIP settings IP address. This website may contain content submitted by users and is for informational purposes only. APC by Schneider Electric shall have no responsibility for the accuracy. AP9. 63. 5CHDevices with an embedded Network Management Card 2 include but are not limited to 2. G MeteredSwitched Rack PDUs AP8. BDF395E750E660/image-size/original?v=mpbl-1&px=-1' alt='Apc Device Configuration Wizard' title='Apc Device Configuration Wizard' />XX, AP8. XX, AP8. XX, AP8. XX, Rack Automatic Transfer Switches AP4. XX, Certain AudioVideo Network Management Enabled products, Smart UPS Online SRT. Environment. All serial numbers. All firmware revisions unless otherwise notedUnconfigured Network Management Card enabled Devices. Network Management Card devices requiring reconfiguration. Cause. A Network Management Card requires TCPIP settings prior to being accessible accessible via a network. Resolution. If you have a Network Management Card 1 In regards to Network Management Card 1 AP9. AP9. 61. 8, AP9. 61. Network Management Card 1 such as a AP7. XX or AP7. 9XX Rack PDU, Environmental Monitoring Unit, etc, there are three available options to configure the Network Management Card NMC with its initial settings the Wizard, terminal emulation localdirect connection, and Address Resolution Protocol ARP. Default boot mode DHCPBoot. Erbsen Auf Halb 6'>Erbsen Auf Halb 6. P With DHCP Option 4. Vendor Cookie required to accept DHCP Offer. By default, all of APCs Network Management Card 1 based devices are configured for a boot mode of DHCPBOOTP. If using DHCP, a vendor cookie DHCP Option 4. If it is not configured on your DHCP server, the card will not accept an IP address. You can use the methods below to configureaccess the card if you do not wish to use DHCPBOOTP. If you have a Network Management Card 2 Default boot mode DHCP Only With DHCP Option 4. Vendor Cookie NOT required to accept DHCP Offer. By default, all of APCs Network Management Card 2 based devices such as a AP8. XXX Next Gen Rack PDU with AOS 5. DHCP Only with no vendor cookie required by default. They will obtain an IP address automatically so you may need to refer to your DHCP server to find out what IP address it obtained. All APC devices have a MAC address that begin with 0. C0 B7 which may help while reviewing your DHCP Client List. In order to configure your Network Management Card enabled device, please pick one of the available configuration methods listed below The Device IP configuration wizard is included on the CD that comes with the cards current v. APCs website v. The wizard must run on a Windows operating system. You can configure the card using the wizard over the network only with v. Prior 3. x versions allow local configuration of the NMC with this program. With the Network Management Card 2 family, the Device IP Configuration Wizard v. Please keep in mind that with certain firmware releases, the NMC can obtain a DHCP address and also prevent the wizard from working correctly. You may want to check your DHCP client list for any MAC addresses beginning with 0. C0 B7, which indicates an APC address. In addition, check the card you are trying to configure. Any card with valid IP settings will have a solid green status LED. If using the wizard over the network, please note, the previously unconfigured NMC must be on the same subnet as the computer running the wizard. An alternative method to using the wizard via the network method may be to use a direct network connection between a computer and the NMC you are trying to configure and running the wizard. Ultimately, your computer and the NMC will be on a peer to peer network which will allow for configuration as well. This wizard will also not work with either network management card family if the network management card was previously configured and not in DHCP or BOOTP boot mode. IP range. Return to Top. Terminal Emulation is a built in function on most operating systems ex Hyper. Terminal. Before using any terminal emulation program, any services using the COM ports must be stopped. For example, if you are running a serial version of APCs Power. Chute software, the APC UPS service must be stopped prior to running the terminal program. Then, follow these instructions lease note that if you have the scroll lock on, Hyper. Terminal will not communicate properly with an APC UPS or accessory. Connect to the UPSdevice serial port using the correct APC configuration cable. Part numbers are below for common devices. Please refer to the users manual if you are not sure or your device is not listed. WARNING Connecting a non APC serial cable to your device can cause unwanted, erratic device behavior. Device Configuration Cable Part Number Most UPSs that have a DB 9 serial port. DB 9 to DB 9 Rack PDU AP7. XX, AP7. 9XX, AP8. XX,AP8. 6XX, AP8. XX, AP8. 9XX9. RJ 1. DB 91st Generation Rack Automatic Transfer Switch AP7. DB 9 to DB 92nd Generation Rack Automatic Transfer Switch AP7. XX, excludes AP7. RJ 1. 2 to DB 94th Generation Rack Automatic Transfer Switch AP4. XX9. 40 0. 14. RJ 1. DB 9Netbotz 2. Environmental Monitoring AP9. AP9. 34. 0, AP9. 32. DB 9 to DB 9Rack Air Removal Unit ACF4. ACF4. 029. 40 0. DB 9 to DB 9This device is NMC2 based so proceed to NMC2 configuration instructions. After connecting the correct cable, start the terminal emulation program of your choice. Configure port settings appropriately for the device you are attached to reference the user manual for the particular device. Commonly used port settings are as follows Device COM Port Settings. Most UPSs that have a DB9 serial port. Rack PDU9. 60. 0 bps, 8 data bits, no parity, 1 stop bit, and no flow control. Generation Rack Automatic Transfer Switch AP7. NMC configuration refer to users manual for more information. Generation Rack Automatic Transfer Switch AP7. XX, excludes AP7. Netbotz 2. 00Environmental Monitoring AP9. AP9. 34. 0, AP9. 32. Rack Air Removal Unit. Apply the port settings to establish the connection. Us Web Coated Swop V2 Profile here. Press lt Enter 3 5 times to display the username prompt. You are now in the control console. Choose NetworkChoose TCPIPChoose Boot modeChange Boot mode to ManualSet the system IP, subnet mask, and default gateway. Accept changes. Press Ctrl C to return to main menu. Download Sample Dae Files Blender. Log out of console to save changes. Now, you can remotely log into the NMC using web access or Telnet. Generation Rack Automatic Transfer Switches for out of the box configuration. Refer to users manual. Network Management Card 2 AP9. AP9. 63. 1 and related accessories require different configuration settings in order to be configured locally. In order to connect to one of these cards, you must use the 9.